wind solar hybrid charge controller3KW48V/96V/220V/240V solar wind hybrid controller

FOB Reference Price:Get Latest Price
$296.00 - $546.00 / Pieces | 1 Piece/Pieces (Min. Order)
Rated Voltage:
96V
Maximum Current:
100A
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Shandong, China
Brand Name:
deming
Model Number:
FKJ-B(PWM) 3KW96V
Application:
Charger Controller, Wind Controller
Product name:
wind solar hybrid power system controller with dump load
Display:
LCD
Warranty:
1 Year/2 Years
Color:
Blue
Function:
Rectifier,charge,control
Charge mode:
PWM Charging
Supply Ability
Supply Ability:
1000 Piece/Pieces per Day wind solar hybrid charge controller solar wind hybrid controller
Packaging & Delivery
Packaging Details
wind solar hybrid charge controller3KW48V/96V/220V/240V solar wind hybrid controller
carton packaging
Port
qingdao,shanghai,tianjin,shenzhen,guangzhou
Picture Example:
package-img

wind turbine solar hybrid system off-grid wind solar controller with dump load 3KW 96V 220V 240V 

 

Product Overviews

 

 

Off-Grid PWM Wind Solar (disel) Hybrid Controller  

FKJ-B model off grid PWM wind solar hybrid controller Product Characteristics

1. The product is manufactured according the JB/T6939.1-2004 industrial standard and GB/T19115.1-2003 national standard also with users’ technical requirements.

2. Big LCD display.The images tell working state visually.Various data show: real-time wind turbine voltage,current,power;solar panel voltage,current,power;battery group voltage, charge current.

3. Two sets of control systems:PWM constant voltage system and three-phase dump load system.

4. When the strong or super-strong wind conditions PWM control to ensure battery charged by the wind turbine with constant voltage and current.

5. When the battery disconnect or damage, the three-phase dump load will start automatically to avoid the wind turbine idling and runaway accident.

6. The protection function of battery: polarity reverse protection, disconnection and damage protection.

7. Over-charging protection of the battery: When the battery is full, the three-phase dump load will work, the wind turbine will brake and stop charge the battery.

8. Auto recharging of battery: When the battery voltage reduces to 108% of the rated voltage,it stops three-phase dump load to recharge battery automatically.

9. The controller is equipped with manual brake switch. To using this switch, the wind turbine will carry out three-phase dump load forcibly.

10. The inside of the controller is equipped with surge arrester. Contain the over voltage into the wind turbine under the bearable voltage of the equipment or system. On the other way, to conduct the strong lightening current into the earth directly to avoid any damage of equipment.

* Solar panel control system is optional.Based on customers' requirement.

* Disel generator port is optional.Control the generator start and stop automatically

* Adopt Modbus Communication protocol. Convenient to carry out the secondary development.

* Adjusting the technical specification via RS485 is available.Convenient to adjust the different wind turbines for professional customers.

* Support WIFI and GPRS.Customers can monitor the real-time working state of the on grid wind power system via PC and mobile and query history working sate.Both Android and OS are compatible in Mobile.

* For the different wind turbine, the controller can be equipped with mechanical yawing, Rotate tail control, furled empennage, mechanical brake,hydraulic brake, electromagnetism brake and other brake functions.

Detailed Images

  

 

 

Technical parameters of off grid wind solar (diesel) hybrid controller 3KW

 

Type

3KW-24Vdc

3KW-48Vdc

3KW-96Vdc

Wind turbine rated power

3KW

3KW

3KW

Wind turbine max. power

6KW

6KW

6KW

*Solar panel power

900Wp

900Wp

900Wp

Battery

24Vdc

48Vdc

96Vdc

Function

Rectifier, charge, control, *DC output

Automatic protection function

Over voltage protection, constant voltage charge, arrester

Manual function

Manual brake

Display mode

LCD+LED

Display content

Wind turbine voltage, current, power; solar panel voltage, current, power; battery voltage, charge current

PWM constant pressure voltage

>29Vdc

>58Vdc

>116Vdc

Wind turbine 3-phase dump load voltage

30±1Vdc

60±1Vdc

120±2Vdc

Wind turbine recharge voltage

27±1Vdc

54±1Vdc

108±2Vdc

*Solar control stop charging voltage

30±1Vdc

60±1Vdc

120±2Vdc

*Solar control recharge voltage

<29Vdc

<58Vdc

<116Vdc

*Diesel generator starting voltage

20±1Vdc

40±1Vdc

80±2Vdc

*Diesel generator off voltage

27±1Vdc

54±1Vdc

108±2Vdc

Self-provided battery connecting wire

>30mm²

>12mm²

>6mm²

PWM fuse

160A

80A

40A

*Solar fuse

50A

25A

12A

Charging fuse

190A

125A

63A

Work environment temperature

-30-60°C

Relative humidity

<90% No condensation

Noise (1m)

<40dB

Degree of protection

IP20(Indoor)IP65 (Outdoors)

Cooling method

Forced air cooling

*Extral Control function (optional)

Yawing, variable pitch, mechanical brake,

hydraulic brake, electromagnetism brake

*Communication interface (optional)

RS485/USB/GPRS/WIFI/Ethernet

*Temperature compensation (optional)

-4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C

Controller Size (mm)  Weight (kg)

580*400*240   23Kg

510*360*240    18Kg

510*360*240    17Kg

Dump load Size (mm)  Weight (kg)

400*410*250   13Kg

400*410*250    13Kg

400*410*250    13Kg

*Above parameter only for reference. Could be custom made to user specifications. 

Payment
Parts

  Service guarantee

         As our corporate users, you enjoy the following service:

        (1) The machine warranty for free in 2 year;

        (2) Technical support;

        (3) Within 24 hours for respond after receiving notification;

        (4) Cost maintenance forever.

        When you confirm the failure of equipment, please promptly contact us and provide the equipment model and complete description of the problem.



        However, any of the following situation happened, are not included in the warranty:

       (1) Non-permitted by the company, went ahead with repair and damage;

       (2) Install or modify arbitrarily;

       (3) Incorrect operation or use;

       (4) Do not depending on the manual to do cleaning or maintenance;

       (5) Abnormal environment condition exceed the specifications, result in damage;

       (6) The deliberate destruction of man-made;

       (7) Irresistible natural disasters.

 

Case

 

Certifications

 

Company Information

 

 

More products

More products